Industrial water treatment chemicals · Manufacturer & global B2B supply[email protected] · +86 177 3480 9172
RYZE Technology logoRYZETECHNOLOGY
APPLICATION

Oil, gas & petrochemical

Oily water separation, produced-water clarification, foam control and heat-exchanger protection in upstream and downstream operations.

Oilfield and refinery water is hot, saline and chemically variable. The same flocculant that works in a cool municipal plant can fail completely at 60 °C and 20,000 mg/L chloride, so the starting point is always the water analysis.

Where the chemistry is needed

StreamProblemChemical route
Produced waterResidual oil, suspended solids, scaleCoagulant + flocculant; scale inhibitor
Refinery wastewaterEmulsified oil, phenols, sulphidePre-treatment + PAC/PAM; carbon polish
Drilling fluids and pitsFoam, fine solidsDefoamer, flocculant
Cooling and heat exchangersScale, corrosion, biofilmInhibitor programme, biocide
Storage and transportWater bottoms, emulsionDemulsifier route with coagulant support

Selection notes

  • High salinity — cationic and anionic PAM behave differently at high ionic strength; test at the actual salinity, not in tap water.
  • High temperature — polymer degrades faster; dose closer to the injection point and use a heat-stable grade.
  • Oil sheen — flocculant will not remove free oil; separation happens upstream and the polymer handles the dispersed solids.
  • Sulphide — can float the floc and smell; pre-treat before coagulation.

Typical ranges

  • PAC: 20–200 ppm in refinery wastewater, higher than municipal because of oil and sulphide load.
  • Anionic PAM: 1–20 ppm for solids flocculation in produced water.
  • Defoamer: 50–500 ppm in drilling-fluid and pit applications.
  • Scale inhibitor: 2–20 ppm in the water system, set by the saturation index.

What goes wrong

  • Floc floats instead of settling — gas from sulphide or dissolved hydrocarbons; degassing is the fix, not more polymer.
  • Polymer works in the lab, fails on site — lab water was cooler and fresher; always test at line temperature and salinity.
  • Heat exchanger fouling returns quickly — inhibitor dose set by make-up flow, but the system has a leak or high cycles; check the water balance.

Send the stream description, temperature, salinity, oil and solids, and the current programme. We propose a route and a trial quantity.

Questions buyers ask

Direct answers

Can municipal-grade PAM be used on produced water?

Sometimes, but high salinity and temperature change the behaviour. Test the grade at the actual salinity and temperature before committing to a container.

How do we stop floc floating in the separator?

Remove the gas first: degas or pre-aerate, and check for sulphide. Floating floc is usually a gas problem, not a polymer problem.

Do you supply demulsifiers?

Our range covers coagulant and flocculant support plus defoamers, scale and corrosion inhibitors. For dedicated demulsifier programmes we confirm the formulation against the emulsion sample.

What data do you need for a quotation?

Stream type, temperature, salinity, oil and suspended solids, target quality, flow and current chemicals. A sample of the emulsion or water shortens the process considerably.

Send your water or material data.

We reply with a product route, indicative dosage and the documents you need.

Contact technical sales ↗