A coal preparation plant recycles its water, so the flocculant is part of the water balance. Poor clarification sends slime back to the plant, raises ash in the product and eventually forces a shutdown.
What is in the water
| Component | Consequence |
|---|---|
| Fine coal and clay slime | Slow settling, high turbidity, thickener overload |
| Residual magnetite (dense medium) | Loss with overflow, higher medium consumption |
| Flotation reagents | Foam in thickener and pumps |
| High solids load after heavy rain | Hydraulic and chemical overload |
Typical route
- Coagulant — PAC 10–40 g/t where clay content is high or the feed is very dilute.
- Anionic PAM — 5–40 g/t dry solids, high molecular weight, injected into the thickener feed launder.
- Defoamer — silicone emulsion where flotation reagent foam blocks the thickener or the vacuum filter.
- Filter aid — the same polymer at reduced dose, or a lower molecular weight grade for disc filters.
Operating notes
- Control by overflow turbidity and underflow density; the target is usually 25–35% solids for the filter feed.
- Keep the polymer dilution at 0.05–0.1% and the line short; diluted solution degrades within hours.
- Magnetic medium recovery benefits indirectly: better clarification means less magnetite in the overflow.
- In winter, cold water slows floc formation; a slightly higher dose or a warmer make-up stream helps.
What goes wrong
- Thickener overflow turbid after a rain event — solids load exceeded the hydraulic design; reduce feed rate and raise dose temporarily, then re-tune.
- Filter cake too wet — floc too fine or the vacuum is inadequate; check dose before changing the filter.
- Foam in the thickener — flotation reagent residue; a silicone defoamer is the practical fix, dosed into the feed.
- Polymer cost rising month on month — often clay content in the feed seam, not the product.
Send the feed solids, ash, PSD and current flocculant. We propose a grade and a g/t band for a thickener trial.