APPLICATION

Municipal & industrial wastewater

From primary coagulation to sludge dewatering and tertiary polishing — the chemical route that keeps discharge limits and sludge volume under control.

Most wastewater chemical problems are one of three: solids that will not settle, sludge that will not dewater, or a dissolved parameter (phosphorus, colour, COD) that biology cannot remove. Each has a different chemistry, and mixing them up is the most expensive mistake in the plant.

Step 1 — what the water is telling you

MeasurementDecides
pH and alkalinityCoagulant window, alkali requirement
SS / TSS and turbidityCoagulant dose, clarifier loading
COD, BOD5Whether biology or chemical polishing is needed
Total phosphorusPAC or metal-salt dose if P-driven
Sludge age, DS and VSPolymer type and conditioning dose
Flow and peak factorDosing capacity, mixing energy

Step 2 — the usual chemical route

  1. Coagulation — PAC 28–30% or PFS, 20–150 ppm, rapid mix 30–60 s.
  2. Flocculation — anionic PAM for mineral solids, cationic for biological sludge, 0.5–5 ppm, slow mix 10–20 min.
  3. Sludge conditioning — cationic PAM 0.2–1.5 kg/t DS before the press or centrifuge.
  4. Tertiary polishing — powdered or granular activated carbon for colour and residual COD; PAC for phosphorus polish.
  5. Odour — plant-extract or microbial deodorizing agent at the sludge and screen areas.

Step 3 — dosage is a range, not a number

Typical starting ranges:

  • PAC: 20–150 ppm product, or roughly 5–40 ppm as Al2O3.
  • Anionic PAM: 0.5–10 ppm in the feed for clarification.
  • Cationic PAM: 0.2–1.5 kg/t dry solids for dewatering.
  • Powdered carbon: 10–100 ppm for colour and COD polish.

A jar test on the actual water narrows these by a factor of two or three, and a plant trial narrows them again.

What goes wrong in practice

  • Polymer consumption creeping up — often incomplete dissolution or polymer aging, not a weaker product.
  • Clarifier sludge rising — floc too light or hydraulic overload; check polymer dose and sludge blanket.
  • Cake solids falling — charge demand changed with sludge age; re-run the conditioning test.
  • Phosphorus limit missed — coagulant dose is solids-driven and below the P requirement; raise the metal dose or add a dedicated step.
  • Foam in the aeration basin — surfactant or filamentous organisms; defoamer is a control measure, not a cure.

Send pH, SS, COD, P, flow and the current dosing. We return a grade and a starting dose, plus the documents the plant needs to trial it.

Questions buyers ask

Direct answers

PAC before or after the biological stage?

Usually before primary clarification for solids and phosphorus, and again as a tertiary polish if the discharge limit is tight. Dosing after biology is less efficient because alkalinity and mixing are poorer.

How do we reduce sludge volume?

Raise cake dryness first through conditioning and machine settings; then reduce the coagulant's inert salt load (higher Al2O3 grade) and cut polymer overdosing. Sludge volume is a dewatering problem before it is a chemical problem.

Which polymer for waste-activated sludge?

Cationic PAM with the charge density matched to the sludge. Young sludge needs a higher charge density than digested sludge; a charge-demand test saves more money than any price negotiation.

Can carbon replace PAC for colour?

Carbon adsorbs dissolved colour that coagulation cannot remove; PAC removes the solids that carry apparent colour. Many plants need both, in that order.

Send your water or material data.

We reply with a product route, indicative dosage and the documents you need.