Quick answer: sludge dewatering is decided by three things in order — the sludge's charge demand, the polymer dose that matches it, and the machine's drainage and pressure settings. Raising the polymer dose without checking charge and machine settings usually produces a stickier cake, not a drier one.
Where the water actually is
Sludge water sits in three places: free water between flocs, interstitial water inside the floc structure, and bound water in the cell mass. Mechanical dewatering removes free and part of the interstitial water. Bound water needs thermal drying or chemical conditioning that changes the cell structure — no press removes it.
That is why cake solids have a practical ceiling: about 20–25% for waste-activated sludge on a belt press, 25–32% on a high-solids centrifuge, higher for digested or thermally conditioned sludge.
Charge demand before dose
Sludge particles are negatively charged; cationic polymer neutralises that charge and bridges the flocs. The correct dose is set by the charge, not by the tonnage.
| Sludge type | Charge behaviour | Practical note |
|---|---|---|
| Waste-activated, young | High negative charge | Higher charge density needed; dose is high |
| Waste-activated, old | Lower charge, more dispersed | Lower density, watch for overdosing |
| Digested | Lower charge, finer solids | Medium density, good drainage |
| Primary + secondary mixed | Variable | Test the actual mix, not the design mix |
| Chemical sludge (PAC/lime) | Already coagulated | Polymer dose low; overdosing is easy |
A charge-demand test — titrating with a standard polymer until the supernatant clears — takes ten minutes and typically explains a 30–50% dose difference between two plants with the same sludge volume.
Conditioning dose
- Cationic PAM 0.2–1.5 kg per tonne of dry solids, with 0.5–1.0 kg/t as the common municipal range.
- Prepare 0.1–0.2% stock, dilute to 0.05% at the injection point, and provide 30–60 seconds of gentle mixing before the machine.
- Too little: free water remains, cake wet, filtrate turbid.
- Too much: cake sticky, cloth blinds, solids climb in the filtrate, and the polymer bill rises with worse results.
The dose curve has a clear minimum: plot cake solids and filtrate solids against polymer dose, and the optimum is where filtrate clarity is acceptable and cake solids peak.
Machine settings
| Setting | Effect | Practical starting point |
|---|---|---|
| Polymer dose | Floc size and strength | From the jar/screen test, then trim on site |
| Conditioning time | Floc maturity | 30–60 s gentle mixing, not in a pump |
| Belt speed | Drainage time and cake thickness | Slower for wet sludge, faster if cake is too dry and cracking |
| Belt tension / pressure | Cake solids | Increase in steps, watch for crushing and cloth wear |
| Gravity drainage zone | Free water removal | Ploughs and deck condition matter more than pressure |
| Centrifuge bowl speed / differential | Cake dryness vs torque | Small differential changes have large effects |
Diagnosing a wet cake
- Filtrate turbid, cake wet — underdose or wrong charge density.
- Filtrate clear, cake wet — drainage or pressure problem, not polymer.
- Cake sticky, cloth blinding — overdose or too high a charge density.
- Solids in filtrate climbing — floc sheared in the feed pump or the dose point is too far upstream.
- Performance falls after a sludge age change — re-run the charge test; do not simply raise the dose.
Data to send
- Sludge type, DS%, VS%, and the machine type.
- Current polymer, dose, cake solids and filtrate solids.
- A 2–5 kg sample and the target cake solids.
That is enough to propose a grade and a dose band, and to say whether the target is physically reachable on the existing machine.