Quick answer: use cationic PAM for organic and biological sludge, anionic PAM for mineral slurries such as tailings, coal and metal hydroxide sludge, and nonionic PAM only for acidic or low-turbidity systems. Then match molecular weight to the separation equipment and charge density to the colloid load, and confirm with a jar test on the real water.
The one-minute answer
| Your material | Start with | Why |
|---|---|---|
| Waste-activated sludge, digested sludge | Cationic, medium molecular weight | Organic solids carry negative charge; cationic polymer neutralises and bridges |
| Belt press or centrifuge feed | Cationic, medium to high charge density | Charge demand is high; overdosing shows as sticky, wet cake |
| Mineral tailings, coal slime | Anionic, high molecular weight | Mineral particles need long chains for fast settling |
| Metal hydroxide sludge | Anionic, medium molecular weight | Floc must be tough enough for a filter press |
| Paper stock retention | Cationic, low molecular weight | Short chains work at the headbox, long chains over-flocculate |
| Acidic or low-turbidity suspension | Nonionic | Charge-neutral bridging where pH limits ionisation |
Charge type decides the family
Colloidal particles carry a surface charge. Most organic and biological solids are negative, so a positively charged polymer both neutralises the charge and bridges the particles. Mineral particles are usually negative too, but the suspension is dense and the goal is settling speed rather than charge neutralisation, which is why anionic high-molecular-weight grades dominate in mining.
A simple field check: add a drop of anionic and a drop of cationic stock solution to two beakers of the same slurry. Whichever produces visible flocs within 30 seconds is the right family. If neither does, the suspension needs coagulation first — the polymer has nothing to bridge.
Molecular weight decides the speed
| Molecular weight | Settling | Shear tolerance | Typical use |
|---|---|---|---|
| Low (5–8 million) | Slower | Good | Retention aids, filtration, fine floc |
| Medium (8–15 million) | Balanced | Moderate | Sludge dewatering, belt press, centrifuge |
| High (15–25 million) | Fast | Poor | Thickeners, tailings, high-solids clarification |
Higher molecular weight is not automatically better. In a centrifugal pump or a high-shear mixer, a very high molecular weight floc breaks apart and the plant compensates by buying more polymer. If the slurry passes through a pump after flocculation, choose medium.
Charge density decides the dose
Charge density is the fraction of the polymer chain that carries charge. Higher density neutralises more charge per kilogram but narrows the operating window: a small overdose collapses the floc or makes the cake sticky.
- Low density (10–20%): tolerant, good for variable sludge.
- Medium (20–40%): the usual starting point for municipal sludge.
- High (40–60%): blood-rich, fat-rich or highly colloidal sludge; also some paper applications.
A charge-demand test — titrating the sludge with a standard cationic polymer until the supernatant clears — gives the number directly and usually explains why a plant is consuming twice the expected dose.
The jar test that settles it
- Take fresh sample, do not let it settle for hours before testing.
- Divide into six beakers of equal volume.
- Add coagulant first if the suspension is colloidal, mix fast for 60 seconds.
- Add polymer at 0.5, 1, 2, 4, 8 ppm equivalents; invert the beakers the same number of times.
- Watch three things: time to first visible floc, floc size, and clarity of the supernatant after 5 minutes.
- Record the dose where clarity stops improving — that is the knee of the curve, and the practical set point is usually 10–20% below it.
For dewatering, finish with a "cake" test: pour the flocculated sludge onto a 200-mesh screen or a piece of filter cloth and observe drainage time and cake firmness. Settling clarity and dewatering quality are not the same thing, and a grade that wins the settle test can lose the press test.
The data to send a supplier
- Suspended solids, pH, and the material type (biological, mineral, chemical).
- Equipment: thickener, DAF, belt press, centrifuge, filter press, and the target cake solids.
- Current product, dose and the result you are getting.
- A 2–5 kg sample if a real trial is needed.
With those four items a supplier can shortlist one or two grades in a day. Without them, any recommendation is a guess with a datasheet attached.